{"id":493,"date":"2025-09-16T04:32:44","date_gmt":"2025-09-16T04:32:44","guid":{"rendered":"https:\/\/xtech-eng.com\/?post_type=product&#038;p=493"},"modified":"2025-12-31T06:55:45","modified_gmt":"2025-12-31T06:55:45","slug":"dc-motor","status":"publish","type":"product","link":"https:\/\/xtech-eng.com\/?product=dc-motor&lang=en","title":{"rendered":"Nippon Gear_DC motor"},"content":{"rendered":"<h1 data-start=\"169\" data-end=\"181\"><strong>Outline<\/strong><\/h1>\n<p data-start=\"182\" data-end=\"264\">There are two proven methods to ensure actuator operation during a power outage:<\/p>\n<ol data-start=\"265\" data-end=\"318\">\n<li data-start=\"265\" data-end=\"290\">\n<p data-start=\"268\" data-end=\"290\">Using a <strong data-start=\"276\" data-end=\"288\">DC motor<\/strong><\/p>\n<\/li>\n<li data-start=\"291\" data-end=\"318\">\n<p data-start=\"294\" data-end=\"318\">Using an <strong data-start=\"303\" data-end=\"316\">air motor<\/strong><\/p>\n<\/li>\n<\/ol>\n<p data-start=\"320\" data-end=\"490\">Historically, <strong data-start=\"334\" data-end=\"361\">DC motor-type actuators<\/strong> have been widely used for <strong data-start=\"388\" data-end=\"418\">emergency isolation valves<\/strong> in power plants, as well as in <strong data-start=\"450\" data-end=\"487\">water supply and sewerage systems<\/strong>.<\/p>\n<h1 data-start=\"497\" data-end=\"528\"><strong>Requirements for DC Motors<\/strong><\/h1>\n<ol data-start=\"529\" data-end=\"827\">\n<li data-start=\"529\" data-end=\"604\">\n<p data-start=\"532\" data-end=\"604\"><strong data-start=\"532\" data-end=\"572\">High starting torque characteristics<\/strong> suitable for valve operation.<\/p>\n<\/li>\n<li data-start=\"605\" data-end=\"827\">\n<p data-start=\"608\" data-end=\"827\"><strong data-start=\"608\" data-end=\"640\">Line-start applicable motors<\/strong>:<br data-start=\"641\" data-end=\"644\" \/>\u2013 Unlike general-purpose DC motors, these do not require current-limiting resistance at startup or a complex switching circuit.<br data-start=\"774\" data-end=\"777\" \/>\u2013 This simplifies the overall circuit design.<\/p>\n<\/li>\n<\/ol>\n<h1><strong>Specifications of DC Motor<\/strong><\/h1>\n<ol data-start=\"866\" data-end=\"1404\">\n<li data-start=\"866\" data-end=\"935\">\n<p data-start=\"869\" data-end=\"935\"><strong data-start=\"869\" data-end=\"888\">Excitation type<\/strong>: Self-excitation \/ cumulative compound type.<\/p>\n<\/li>\n<li data-start=\"936\" data-end=\"1031\">\n<p data-start=\"939\" data-end=\"1031\"><strong data-start=\"939\" data-end=\"963\">Power supply options<\/strong>:<br data-start=\"964\" data-end=\"967\" \/>\u2013 100 V, 110 V, 115 V<br data-start=\"991\" data-end=\"994\" \/>\u2013 200 V, 230 V, 250 V (optional)<\/p>\n<\/li>\n<li data-start=\"1032\" data-end=\"1146\">\n<p data-start=\"1035\" data-end=\"1146\"><strong data-start=\"1035\" data-end=\"1077\">Size (output based on starting torque)<\/strong>:<br data-start=\"1078\" data-end=\"1081\" \/>#2, #5, #7.5, #10, #15, #25, #40, #60, #80, #100, #150, #200<\/p>\n<\/li>\n<li data-start=\"1147\" data-end=\"1378\">\n<p data-start=\"1150\" data-end=\"1378\"><strong data-start=\"1150\" data-end=\"1188\">Operating time (Short-time rating)<\/strong>:<br data-start=\"1189\" data-end=\"1192\" \/>\u2013 20% load (Intermediate load)<br data-start=\"1225\" data-end=\"1228\" \/>\u2022 #2 to #25: 15 mins<br data-start=\"1253\" data-end=\"1256\" \/>\u2022 #40 to #200: 5 mins<br data-start=\"1282\" data-end=\"1285\" \/>\u2013 40% load (Intermediate load)<br data-start=\"1318\" data-end=\"1321\" \/>\u2022 #2 to #25: 7.5 mins<br data-start=\"1347\" data-end=\"1350\" \/>\u2022 #40 to #200: 2 mins<\/p>\n<\/li>\n<li data-start=\"1379\" data-end=\"1404\">\n<p data-start=\"1382\" data-end=\"1404\"><strong data-start=\"1382\" data-end=\"1402\">Brake (Optional)<\/strong><\/p>\n<\/li>\n<\/ol>\n<h1 class=\"title_lineSimple\"><strong>DC motor connection diagram<\/strong><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1526\" src=\"https:\/\/www.nippon-gear.jp\/cms\/content\/uploads\/img_td01_big.jpg\" alt=\"\" width=\"700\" height=\"580\" \/><\/p>\n<p><em><strong>Notes (Connection Diagram &amp; Symbols)<\/strong><\/em><\/p>\n<p data-start=\"1453\" data-end=\"1565\">\u2013 <strong data-start=\"1455\" data-end=\"1462\">R\/C<\/strong>: Reversible electromagnetic switch<br data-start=\"1497\" data-end=\"1500\" \/>\u2013 <strong data-start=\"1502\" data-end=\"1509\">51H<\/strong>: Thermal relay heater<br data-start=\"1531\" data-end=\"1534\" \/>\u2013 <strong data-start=\"1536\" data-end=\"1541\">R<\/strong>: Discharge resistance<\/p>\n<p data-start=\"1567\" data-end=\"1583\"><strong data-start=\"1567\" data-end=\"1580\">Important<\/strong>:<\/p>\n<ol data-start=\"1584\" data-end=\"1794\">\n<li data-start=\"1584\" data-end=\"1638\">\n<p data-start=\"1587\" data-end=\"1638\">External wiring to <strong data-start=\"1606\" data-end=\"1621\">E2 terminal<\/strong> is prohibited.<\/p>\n<\/li>\n<li data-start=\"1639\" data-end=\"1679\">\n<p data-start=\"1642\" data-end=\"1679\">\u201cR\u201d indicates discharge resistance.<\/p>\n<\/li>\n<li data-start=\"1680\" data-end=\"1794\">\n<p data-start=\"1683\" data-end=\"1794\">For motor size <strong data-start=\"1698\" data-end=\"1716\">#7.5 and above<\/strong> (with interpole), <strong data-start=\"1735\" data-end=\"1741\">B2<\/strong> is used instead of <strong data-start=\"1761\" data-end=\"1767\">A2<\/strong> as the terminal marking.<\/p>\n<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>Outline There are two proven methods to ensure actuator operation during a power outage: Using a DC motor Using an air motor Historically, DC motor-type actuators have been widely used for emergency isolation valves in power plants, as well as in water supply and sewerage systems. Requirements for DC Motors High starting torque characteristics suitable&#8230;<\/p>\n","protected":false},"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[201],"product_tag":[],"class_list":{"0":"post-493","1":"product","2":"type-product","3":"status-publish","5":"product_cat-special-motor-option-en-en","7":"first","8":"instock","9":"shipping-taxable","10":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/xtech-eng.com\/index.php?rest_route=\/wp\/v2\/product\/493","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/xtech-eng.com\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/xtech-eng.com\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/xtech-eng.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=493"}],"wp:attachment":[{"href":"https:\/\/xtech-eng.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=493"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/xtech-eng.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=493"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/xtech-eng.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=493"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/xtech-eng.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=493"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}